Delta DRL-48V120W1EN Lyte II Serisi Din-Rail 120W 48V 2.5A Power Supply

Output
Output Current2.5A
Output Voltage48V
Output Voltage Range43.2-2.8Vdc
Output Voltage Adjustment Range43.2-52.8Vdc
Output Power120W
Line Regulation± 0.5% @ 115Vac & 230Vac
Load Regulation± 0.5%
PARD< 200mVpp @ 0°C to +70°C
< 600mVpp @ -30°C to 0°C
Start Up Time500ms typ. @ 115Vac & 230Vac
Hold Up Time10ms typ. @ 115Vac (100% load)
16ms typ. @ 230Vac (100% load)
Dynamic Response (overshoot & undershoot O/P Voltage)± 10% @ 115Vac & 230Vac input, 10-100% load (Slew Rate: 2.5A/μS, 50% duty cycle @ 5Hz & 10KHz)
Start Up with Capacitive Loads3,000µF Max
Rise Time30ms typ. @ 115Vac & 230Vac
Input
Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current2.1 typ. @115Vac, 1.3Atyp.@230Vac
Efficiency at 100% load89.5%typ.@230Vac
Max. Inrush Current35A typ.@230Vac
Leakage Current< 0.5mA @ 240Vac
Case Chassis/CoverAluminum / SGCC
IndicatorGreen LED (DC OK)
Cooling SystemConvection
Input Terminal3 pins (rated 300V/30A)
Output Terminal4 pins (Rated 300V/20A)
Noise Sound Pressure Level (SPL)< 25dBA
Mounting RailStandard TS35 DIN Rail in accordance with EN 60715
Unit Weight0.45kg (0.99 lb)
Dimensions123.6 x 30 x 117.2 mm
4.87” x 1.18” x 4.61”
Environment
Vibration (operating )IEC 60068-2-6, Sine Wave: 10Hz to 500Hz @ 19.6 m/s² (2G peak); 10 min per cycle, 60 min for X direction
Shock Test (Operating)IEC 60068-2-27, Half Sine Wave: 10G for duration of 11ms; 1 time in X axis
Operating Temperature-30°C to +70°C (-40°C Cold Start)
Storage Temperature-40°C to +85°C
Power DE rating> 40°C de-rate power by 1.67 % / °C @115Vac
> 50°C de-rate power by 2.5 % / °C @230Vac
Operating Humidity20 to 90% RH (Non-Condensing)
Shock Test (non operating )IEC 60068-2-27, Half Sine Wave: 50G for duration of 11ms; 3 times per direction, 9 times in total
Vibration (non operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 20 min per axis for all X, Y, Z direction
Operating Altitude0 to 5,000 Meters (16,400 ft.)
Pollution Degree2
Over Voltage CategoryII (Compliance to EN 62477-1 OVC III with 2000 meters altitude)
Protections
Overvoltage<64.8V, SELV Output, Latch Mode
Overload / Overcurrent105 – 150% of rated load current, Auto-recovery
Continuous current limit Mode*5 (Vo>80%)
Over TemperatureLatch Mode
Short CircuitHiccup Mode, Non-Latching (Auto-Recovery when the fault is removed)
Protection Against ShockClass I with Primary Earth connection
Reliability
MTBF> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac & 230Vac, O/P: 100% load, Ta: 25°C
Expected Cap Life Time10 years (230Vac, 50% load @ 40°C)
Safety
Electrical SafetyCB scheme : IEC 62368-1, IEC 60950-1, IEC 61010-1 & -2-201
TUV Bauart : EN 62368-1, EN 61010-1 & -2-201
UL/cUL : UL 62368-1
CCC : GB4943.1
EAC : TP TC 004/2011
CEIn conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EMC
EmissionCISPR 32, EN 55032, EN 61000-6-4, AS/NZS CISPR32, EN 61204-3
Compliance to FCC Title 47, EN 61000-6-3: Class B
ImmunityEN 55035, EN 61000-6-2
Compliance to EN 61000-6-1
Harmonic Current EmissionsIEC/EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN 61000-3-3
ESD ImmunityIEC 61000-4-2
Radiated ImmunityIEC 61000-4-3
EFTIEC 61000-4-4
SurgeIEC 61000-4-5
Magnetic FieldIEC 61000-4-8
Voltage DipsIEC 61000-4-11
Component Power Supply for General UseEN 61204-3

 

Markalar